TERMINALS OPERATION
- 12V/24V Selector – Move jumper with handle to 12 or 24 to select coil voltage to be used. Default is 12vdc
- COIL – Apply selected voltage to terminals 1 & 2 to energize contacts.
- N/O - COM - N/C Terminals are the relay contacts. COM and N/O are Normally Open. They close when the relay is energized.
- COM and N/C are Normally Closed. They open when the relay is energized.
- GREEN LED ON indicates the relay is energized. When LED is OFF the relay is de-energized.
Features
- Heavy-Duty 40 Amp
- Ideal for driving Strike Bars
- Single Pole Double Throw
- Selectable Coil 12/24 VDC
- BI-Directional Coil Spike
- Protection Built-In
- BI-Directional LED Shows Relay
- Energized with Either Polarity
- Mounting Holes with Pre-mounted
- Double Sided Tape
- Very Small
- RT-14HD (4-Pak) Break Apart
Specifications
- Coil Current at 12 or 24VDC ............. 150mA

- Contact Ratings .............. 40 Amp at 75vdc
- Contact Resistance .................. 50m ohm
- Operate time ...................... 10ms Max
- Ambient Temperature ......... -40oC to +85oC
- Humidity ..................... 20 to 85% R.H
- Terminal Block ........... .2” Center 14-28AWG
- Operation Life ..... 1,000,000 loaded cycles
- Dimensions: RT-1HD .... 1.66” X 1.53” X 1.2”H
- RoHS Lead Free ........................... Yes
Specifications are subject to change without notice.