SPS-3

3/1.5A Switching Power Supply with Charger

12/24 VDC Selectable Output

The SPS-3 are heavy duty self contained, efficient clean with linear performance off-line switching power supplies that are selectable between 12 VDC at 3A, and 24 VDC at 1.5A. With the universal AC input, these supplies may be connected anywhere in the world with no plug-in transformer or any alterations. These power supplies have exceptional brown out capability with operation down to 60 VAC. The extensive filtering system provides a very clean DC output with linear performance. All of the supplies are power limited and thermally protected. All output faults are self restoring.

The SPS-3 has a precision lead acid battery(s) charger that obtains maximum battery life while providing a 12 or 24 VDC uninterruptible power supply. The SPS-3 are protected against Battery(s) reversal, shorting or overloading.

Before connecting load and battery(s), set 12/24V selector jumpers to the desired voltage. Caution, damage will occur if jumpers are moved with DC output load or Battery connected. Confirm proper voltage before connecting devices.

The SPS-3 has the additional supervisory features of a set of form “C” relay contacts that indicates AC power status, and a special electronic circuit that limits the output current to provide class II power limiting and load disconnect when battery(s) is depleted.

  • SPS-3 Series - 12/24 Power Supply 12 VDC @ 3A at 24 VDC @ 1.5A
  • SPS-3 - 12/24 Supervised Power Supply/Charger

Features 

  • Small – Self Contained – Efficient
  • Exceeds 2006 no load power consumption and efficiency standards
  • Universal AC Input 90-250 VAC
  • Extraordinary Brown Out Capability, Operational from 60-264 VAC
  • 12VDC 3A/24VDC 1.5A Selectable Continuous Duty
  • Very Clean Output - 10 mv ripple rms
  • Input and Output Surge Protection
  • Power Limited Output with Thermal Protection
  • AC and DC LED’s
  • Precise Battery Regulation for all sealed Lead Acid Battery(s)
  • Battery Online, No Drop or Switch Over with AC Power Fail
  • Reverse Battery Protection
  • Comes with plug in battery cable assembly
  • UL and cUL tested to standards UL 603 Power Supplies Burglar, UL 294 Access Control and ULC-S318-96 Canadian Standard for Power supplies for Burglar Alarm Systems
  • Relay “C” Contacts Indicates AC Power Status
  • Low Battery Disconnect (Battery Cut-off)
  • Class II Power Limited DC Output &SP-3V

Specifications

  • AC Input: L, N, G - 3P Orange Terminal block
  • Safety block with recessed hardware insulation that will accept up to 12AWG
  • L= Line, N= Neutral, and G = Ground
  • Optional 3 wire line cord P/N: ................    HA-LC3SZIP
  • AC Input Rating .............................   90-250 VAC/50W
  •       AC Input Operational .....................    60-264VAC
  • AC LED Indicator (Next to AC Input Terminal)
  • The AC indicator is a bi-color green and red led.
  • AC Line Fuse
  • Fuse:     ...................   GMA-2 5 mm x 20 mm 2A 250v fast
  • DC VOLTAGE SELECTOR JUMPER J1
  • The selector jumper J1 selects the voltage to 12v or 24VDC.  As marked on the PCB, jumping 1&2 and 3&4 sets the supply to 12v.  Jumping 2&3 sets the supply to 24VDC.  CAUTION To prevent damage, remove DC load and battery(s) connections before switching selector J1 jumpers
  • DC OUTPUTS: ................................ 2P Terminal block
  • Output voltage Nominal ..........................  12 VDC/24 VDC
  • Output voltage Typical  ..................   AC on 13.70/27.40
  • Output continuous current 12v/24v  ..................  3A/1.5A
  • Output ripple & noise @ 80% load  ............... 10mv rms Typ
  • Current Overload Short Circuit Protection ...............  Yes
  • Thermal runaway Protection  ............................   Yes
  • Current Overload and Thermal shutdown will auto-restart without removing load.
  • SPS-3 Class II Electronic Power limiting   ..............  Yes
  • Ambient operating temperature range ........   -30oF to +130oF
  • Storage Temperature  ........................   -60oF to 190oF
  • Switching Frequency   ..............................    132KHz
  • DC LED Indicator (Adjacent to DC Output) ................  Red
  • Battery Charging: (Header plug marked [–Bat+])
  • The battery charger is precision set to float charge 12v or 24V sealed or wet lead acid batteries.  Two 12v batteries are connected in series for 24V.  A 12” battery cable assembly is provided that plugs from module to battery.  Red (+) 12VDC, Black (–) Neg.
  • Optional 36” battery cable (1) P/N: ..............   WA-36IBAT
  • Battery(s), any type of lead acid ............... 12v 4AH-40AH
  • UL Evaluated with 7AH Battery
  • Battery(s) PTC self resetting Circuit Breaker ........  3A PTC
  • Battery(s) Reverse hookup protection  ...................  Yes
  • To estimate the recharge time in hours for depleted battery(s), multiply the AH rating times 4 (AH x 4).  As an example, a 24V system with two depleted 12V 7AH batteries would take about 28 hours to re-charge. View battery standby selection table.
  • SPS-3 Supervised added features:
  • DC Output Class II Power Limited  ....................... Yes
  • Battery Cut-Off Battery Disconnect 12v/24v  ............ 9/18v
  • AC Status Output Relay: ..................  3P Terminal block
  • AC Fail “C” contacts rating ......................  2A/120VAC
  • Three position AC fail terminal block marked “NO, C, NC” are shown in the Normal, energized, AC ON condition.
  • Either No AC or a dead short on the output, tripping the Class II will cause an AC power fail condition.
  • Physical 
    • Module Dimensions  .................. 4.84”L x 3.73”W x 1.9”H 
    • Height includes 7/16” standoffs, not provided with module only.
    • Mounting Holes Center to Center ............. 4.50”W x 3.41”H
    • SPS-3 module only Weight ............................... 10oz
    • SPS-3ES (SPS-3 in small enclosure) .......... 8” x 9” x 3.50”
    • SPS-3ES (with enclosure) Weight ...................... 4.7 lbs
  • Approvals
    • SPS-3 meets safety UL1950 & EN60950
    • Ø     UL and cUL tested to standards UL 603 Power Supplies Burglar, UL 294 Access Control and ULC-S318-96 Canadian Standard for Power supplies for Burglar Alarm Systems

Specifications are subject to change without notice

Product Options

SPS-3 Supervised Power Supply/Charger module

-ES (PS-89)
-E (PS-1485)
-4 (PDM-4
-8C (PDM-8C)

-ACI
-FT (PDD-FT)

Mounted in 8”x9” Enclosure
Mounted in 14”x8.5’ Enclosure
With 1, 4 Output fused distribution board
With 1, 8 Output distribution w/PTC’s
See comments regarding PTC’s on PDM Distribution Tech Sales
With 1, Access Control & Fire Interface