The LP(S)-2.5 becomes an uninterruptible 12 or 24 VDC 2.5A DC power supply when used with an appropriate transformer and lead acid stand by battery. These power supplies are commercial units designed to run security equipment 24 hours a day every day. The output is clean, continuous, linear DC that can be used to power the most sensitive security devices. These units can be paralleled to double output current. Selecting 12v or 24v with the 12/24 programming jumper sets the DC output, battery charge voltage and trip points for the supervisory relays. The battery charger will precisely charge a Sealed, Gel, or wet Lead Acid Battery. The maximum charge current to the Battery(s) is limited to a maximum of 200ma to provide the maximum DC output when using a plug in transformer. The DC output is protected against shorts and overloading with its electronic circuitry and DC output auto resetting 3A PTC circuit breaker. Because the LP(S)-2.5 can use all of the available power of a 50VA transformer it is important that when using a plug in transformer to use one with an autoresetting circuit breaker instead of a fixed non replaceable fuse. See ratings details in the specifications below. Unlike the LP(S)-2, that uses a fuse for the Battery, the LP(S)-2.5 can not be used to power high inrush current devices that draw more than 3As such as crash bar exit devices. To test the standby battery It is recommended that on a regular basis, the output should be checked for proper voltage and current while the AC power is disconnected.

Specifications / Instructions

Input AC Transformer

  • Terminals 1 & 2 identified by AC
  • Terminals 1 & 2 identified by ................................... AC
  • Maximum Voltage ................................................. 28 VAC
  • 12 VDC at 2.5A DC Output requires ......... 16 VAC at 56VA
  • 12 VDC at 2.20A DC Output requires ........ 16 VAC at 50VA
  • 12 VDC at 1.75A DC Output requires ....... 16 VAC at 40VA
  • 24 VDC at 2.5A DC Output requires ......... 24 VAC at 76VA
  • 24 VDC at 1.4A DC Output requires ......... 24 VAC at 50VA
  • Note: When selected for 12 VDC output and using a
  • 24 VAC transformer, limit the output current to less than
  • 900ma. to avoid overheating power supply.
  • AC LED Indicator ............................................ Red LED
  • DC Output Voltage Selector .................. 12/24 Jumper
  • CAUTION Select voltage before any connections are
  • made.
  • DC OUTPUT
  • Terminal 3 & 4 identified by ..................................... DC
  • DC Output voltage Nominal ....................... 12 VDC/24 VDC
  • Output voltage Typical ................... 13.65 VDC/27.30 VDC
  • With proper transformer
  • DC Output Current continuous rating ........................ 2A
  • DC Output Maximum ................................................. 3A
  • Battery Charge maximum limited ....................... 200ma
  • Maximum Output holding current ............................. 3A
  • Ripple @ 80% load ................................... 30mv pp Typ
  • Short circuit current limiting .................................... Yes
  • Reverse battery hook up protection ........................ Yes
  • 1 year long term Stability .................................. .03 VDC

Paralleling Units for more power

Daisy chain each pin together. Pin 1 to 1, 2 to 2, 3 to 3
and pin 4 to 4. It is very important to keep the polarity of
the pins the same. Use just one battery port connection
and trouble relay if applicable. The VA rating for the
Transformer must be at least doubled.

LPS-2.5 Supervised Functions Trbl & Bat Disconnect:

  • Trouble Output: 3P Terminal block - annunciates low battery & AC Fail “C” contacts rating ............ 2A/120 VAC
  • Trouble Trip Point ....................................... 12.2/24.4 VDC

Three position trouble terminal block is marked “NO, C, NC”
are shown in the Normal, energized, no trouble condition.

Battery Disconnect

  • Battery Disconnect Voltage .................. 9.9 VDC/19.8 VDC
  • Battery Cutoff Relay is normally energized for Fail Safe operation.

Battery Charging: (Header plug marked [–Bat+])

The battery charger is precision set to float charge 12V or 24V Sealed, Gel or wet lead acid batteries. Two 12V batteries are connected in series for 24V. A 15” battery cable assembly is provided to connect the module to a battery. Red (+) 12 VDC, Black (–) Neg.

  • Optional 12” cable assembly for connecting two
  • 12v batteries in series for 24volts ......................... 24SW
  • Optional 36” battery cable (1) P/N: .............. WA-36IBAT
  • Amp Hour capacity range .......................... 4AH-100AH
  • The rechargeA Rate ..................................... 100ma
  • Hours to recharge = Bat AH capacity /Amp Rate

To select battery(s), see standy selection table www.securitypower.com/an3batby.pdf .

Environmental:

  • Humidity ............................... 95% RH Non Condensing
  • Ts Storage Temperature ......................... -40oC – 85oC
  • Ot Operating Temperature Range 100% rating:
  •  Ot module only ................................ -20oC – 36oC
  •  Ot mounted in Enclosure ................ -20oC – 26oC
  •  Each 1.4% load reduction increases Ot by: ......1oC

Mechanical Characteristics:

  • Center-to-Center Terminal Block Spacing with Wire ready self Clamping Screws ................................. .375”
  • Module Size .................... 3 ¾”H x 3 11/16”W x 1 5/8”D
  • Mounting Holes Center-to-Center .....3 5/16” W 3 7/16”H
  • “ES” Enclosure size ............................ 8”W x 9”H x 3.5”D
  • “E” Enclosure size ............................ 14”W x 9”H x 3.5”D
  • LPS-2.5 module ................................................... 3.2oz
  • 8x9 Enclosure ...................................................... 3.8lbs
  • 100va Transformer .............................................. 2.8lbs
  • 50va Plug in Transformer .................................... 1.7lbs

Safety

  • LP-2.5/LPS-2.5 meets safety ......... UL1950 & EN60950 Lead Free RoHs compliant

Technical Sales / Instructions

  • LP-2.5 12/24 VDC @ 2.5A Linear Power Supply Charger module LP-2.5 Shown
  • LP(S)-2.5 12/24 VDC @ 2.5A Supervised Power Supply Charger
  • module (S) may be added to any configuration
  • LP-5 12/24 VDC @ 4A Two LP-2.5’s connected together
  • LP-2.5EST12 mounted in a 8”x 9” Enclosure with UL 16 VAC 50VA
  • Class II plug in Transformer
  • LP-2.5EST24 mounted in a 8”x 9” Enclosure with UL 24 VAC 50va
  • Class II plug in Transformer
  • LP-2.5T12 Module with UL 16 VAC 50VA plug in Class II plug in
  • Transformer
  • LP-2.5T24 Module with UL 24 VAC 50VA plug in Class II plug in
  • Transformer
  • LP-2.5EX12D4 mounted in a 14”x8” Enclosure with UL
  • 16 VAC 56VA open frame transformer and 4 fused outputs
  • LP-2.5EX24D4 mounted in a 14”x8” Enclosure with 24 VAC 100VA
  • Features LP-2.5 & LPS-2.5:
  • 12/24 VDC @ 2.5A Jumper Selectable
  • Units may be Paralleled to Double Output Current (LP-5)
  • PTC Circuit Breakers protect Battery and Output
  • Reversed Battery Protected
  • Electronic current limiting
  • Precise Output Regulation for Charging
  • Sealed Lead Acid or Gel Type Batteries
  • Battery Online, No Switch Over with AC Power Fail
  • Input and Output are Surge Protected
  • Power LED Indicator
  • Wire Ready Self Clamping Terminal Screws
  • 18" Battery Leads provided with Quick Plug
  • LPS-2.5 Supervised Features:
  • Trouble Relay “C” Contacts Indicates
  • Low Battery and AC Power Fail
  • Battery Cut-Off Relay Disconnects Battery(s) when
  • Depleted, Preventing Deep Discharge