Operating Voltage
..................................... 10V - 29VDC
Operating Current @ 12VDC Relay
De-energized ................ .5mA
Operating Current @ 12VDC Relay
Energized ................... 30mA
DC Does not Have to be Filtered
Operating Temperature
Range ......................... -50F to 150F
Relay Contacts (Sealed)
............................ 15Amps @ 220V
Made in the USA
Double Stick Tape Pre-mounted and
Mounting Holes
Small Size:
.................................. 2.4”L x 2.7W” x 1”H
EXPLANATION OF
TERMINALS
1) Start Trigger Input
Terminal #1 Starts Timing with + or - Applied or Removed.
2) Power Input Terminals
#2+ and #3- /12-24VDC
3) Form C RELAY Contacts
Terminals #4, #5, & #6 with No Power Applied, are as
Follows:
#4 Normally Open Contact
#5 Swing Arm (Common)
#6 Normally Closed Contact
EXPLANATION OF JUMPERS
INTRNL:
Internal (- or +) Selecting this applies either a positive
or a negative voltage inside the timer to the Start
terminal. This feature provides more versatility to the
timer. Default is (-).
DELAY: When
PICK is selected, at start, the timer waits the adjusted
time to energize the relay. When DROP is selected the timer
energizes at Start then waits the adjusted time to
de-energize. Default is (PICK).
START: Start
timer with either a positive or a negative input. Default
is (+).
MIN / SEC: This
selects 0-60 seconds or 0-60 minutes. Default is Seconds.
FLASH: By
selecting (Y)es the timer repeats itself until you remove
the Start. When the default (N) is selected the timer does
not repeat automatically.
|