PDD-8PCI DC Power
Distribution with Supervised Interface module Distributed Power Control Interface for Fire, Access, HVAC, Elevator, and Security Features:
|
|
|---|
|
DESCRIPTION |
|||||||||
|---|---|---|---|---|---|---|---|---|---|
| The PDD-8PCI power distribution control
interface converts a main non-power limited DC power source to 8 class
II power-limited outputs that can be controlled by a (FACP) Fire Alarm Control
Panel. Each output can be selectively set (J1-J8) to turn ON or
to Turn OFF, Trigger disabled always ON when triggered by the panel.
The FACP or other control system can interface to the PDD-8PCI with either
of two or both supervised trigger inputs. One trigger is activated
with a reverse polarity voltage from a FACP. This trigger is fully
isolated with an optical isolator. The other trigger is an (EOL) 2.2K
End Line Resister input which will accept a (N/O) Normally Open switch or
a (N/C) Normally Closed switch. When triggered, the Trigger Transfer Relay removes power from the NORM + buss and transfers it to the TRIG + buss. Jumpers J1-J8 determine which buss each output is connected to. The triggered form C contacts also drop off normal when triggered and the Red (TRG) LED turns on. These contacts can be used to daisy chain other PDD-9ST, latch, or provide feedback to a system. The Trouble Form C Relay drops off Normal if any one of the PTC circuit breakers is tripped, or main power/fuse is lost. The Green (TRB) LED is ON during normal operation, It goes off with trouble. All three relays are Fail-Safe, energized in the normal condition. Each output has a Green LED that is on when the associated output is ON. Typical applications for a Fire Alarm System would include adding remote Bells and anunciators, closing dampers, turning off HVAC fans, unlocking fail secure and fail safe doors, and / or returning elevators to first floor. The installation instructions illustrate these applications. The PDD-8PCI is available as a module or mounted in an enclosure with any of our DC Power Supplies. |
|||||||||
|
SPECIFICATIONS |
|||||||||
|
Input Voltage:
11–28VDC Current, Typical, with No Output Load: 90-160mA Outputs 1–8 continuous duty each: 1.23 Amps Voltage Trigger: 20% < Input min. 30vdc max. Voltage Trigger isolation Optical EOL (End of Line) Trigger: +-50% of 2.2K ohms Transfer Relay Contacts: 15Amps Trouble Form C Contacts: 2A 120vac/1A 220vac Triggered Form C Contacts: 2A 120vac/1A 220vac |
|||||||||
|
Specifications are subject to change without notice |
Electronic Security Devices 6111 Southfront Rd #J Livermore, CA 94551 |
E-mail: ESD@SecurityPower.com