LP-1
1 Amp
Linear Power Supply/Charger 6V/12V/24V Selectable Life Time Warranty Features:
|
![]() |
|---|
|
DESCRIPTION |
|||||||||
|---|---|---|---|---|---|---|---|---|---|
| The LP-1 becomes an
uninterruptable power supply when
used with a transformer and battery. The
output of the LP-1 is a clean smooth continuous DC power which can be
used to
power the most sensitive electronic controls. The LP-1 output and battery charge voltage is selected by moving the programming jumper to 6V, 12V or 24V. The voltage selected is factory preset to precisely charge a Sealed, Liquid, or Gel Type Lead Acid Battery(s). For calculating standby current, recharge times, and available current, refer to the tables and the specifications on the backside of this bulletin. To test the battery and fuse: It is recommended that on a regular basis, the output should be checked for proper voltage and current while the AC power is removed. Ordering Information LP-1 LP-1E LP-1 mounted in a 8" x 9" Cabinet LP-1T12 LP-1T24 |
|||||||||
|
SPECIFICATIONS |
|||||||||
| Output DC
Voltages are optimized for Sealed Lead Acid or
Gel Type Battery Charging. Caution: Select your output voltage before connecting AC. 6V Selection ....................................... 6.80vdc 12V Selection ....................................... 13.75vdc 24V Selection ....................................... 27.50vdc Output Current Note: If you are using a standby battery, subtract at least 150ma from your continuous current for charging the battery. This allows up to 850ma of continuous current for your output load. See transformer selection table below. Maximum Output Current of Supply ......................... 1.5A Thermal Shutdown ....................................... 180oF Intermittent Current with Battery ....................... 4 Amps Maximum Battery Current with 3AGC 4 Amp Standard Fuse .. 4 Amps Maximum Battery Current with Optional Auto Resetting Circuit Breaker ............................................ 2 Amps Typical Regulation from No Load to Full Rated Current ...... .05% Typical Ripple and Noise @ Full Load ....................... 50mv Voltage Change after 1 year of Continuous Operation (Long Term Stability) ........................................................... .02VDC Center-to-Center Terminal Block Spacing with Self Clamping Screws ............................................................ .375” Module Size ................................ 3.06”H x 2.43”W x 2”D Mounting Holes Center-to-Center ............... 2 1/16”W x 2 5/8”H Input AC Transformer Selection Table: Transformer/ min. VA 12 vac@20VA 16vac@20VA 25-28vac@40VA 24vac@40VA 24vac@40VA 24vac@40VA See LP-1 Tech Sales pdf file for Battery Standby and Recharge Time Table TECHNICAL SALES BULLETIN LP-1 |
|||||||||
|
Specifications are subject to change without notice |
Electronic Security Devices 6111 Southfront Rd #J Livermore, CA 94551 |
E-mail: ESD@SecurityPower.com